Ecobee fan runtime. On the thermostat: Go to the Main Menu > General > Settings &...

Their documentation and examples state if the heating/cooling

The ecobee Energy Management System Si (EMS Si) is an ecobee smart thermostat designed for the commercial market. ... This setting is only available the Comp to Aux Temp Delta and Comp to Aux Runtime settings are both set to Auto (default) ... Heat Fan Control Configures the furnace fan to be controlled by the EMS Si or the HVAC system during ...Step 3: Add Ecobee Integration. First, log into your Home Assistant web interface. It should be something like 192.168.68.124:8123. Click the Configuration tab, and then + Add Integration. Search for " ecobee". Add your API key that was generated from Step 2. You will then see a screen like below asking you to please authorize this app at ...The runtime reports have never worked consistently for me for the 2 years I've owned an Ecobee. I have pretty much given up on them. If you like Excel and want extensive data, you can download the data really easily for any time period you choose. But for quick analysis, beestat is the way to go.Heat Dissipation Time: The amount of time the fan will run after the heat set point has been reached and the call for heat has been turned off. Running the fan for a period of time allows for any heated air left in the ducts to circulate throughout the home. The time is adjustable from 0 to 900 seconds. The default value is 30 seconds.I have an Ecobee 3 in a rental unit (nicer and simpler user UI than CT100). One feature that we like about it is being able to set a minimum fan runtime so during those days were the temperature doesn’t kick off the HVAC you can still move/filter the air. Has anyone had success writing luup or other code to replicate this on the CT100? Thanks - JackLive comfortably and save automatically. Our smart thermostats are designed to lower energy costs and are so smart they can pay for themselves in about a year. Save up to 26% * on heating and cooling costs and avoid wasting $284 on average per year. 1. Control from anywhere from a smartphone, tablet or Apple Watch.So if your current set point is 78 and you have it programmed to go to 72 by 8PM, the Ecobee will show a set point of 78 while it also shows a room temp decreasing. Once 8PM rolls around, the set point will change. If you set the system to OFF, but you don't turn off the auto fan runtime, the fans will still run.Creating a Fan Hold will allow your ecobee to run the fan for a set period or indefinitely. On the ecobee Thermostat. Go to Main Menu > Fan > On then select the desired runtime from the drop-down menu. On the ecobee App. Tap Home > Tap the Thermostat > tap the Toggle on the bottom right > Set fan hold, then tap on your desired Fan Hold time.Schedule a vacation. On the thermostat. Go to Main Menu > General > Vacation, then select the Plus icon. Select I Depart to set the start date and time. Select I Return to set the end date and time. Set your desired temperatures and fan runtime by selecting Vacation Settings. Then select Save.In an international where vitality efficiency is popping into more and more main, many folks are turning to know-how and innovative tips to turn into moreI am using an ecobee with voice to control a heat only system on a 2 story house. I like using the fan runtime to equalize the temperature difference between the floors. On a cool day I can get away with setting to 5min but on hotter days it works best at 15 or more.Very normal. A/C on reduces humidity but the fan running adds to it. If you're running the fan by itself, the humidity will increase. It's possible the opening behind your thermostat might be blowing humid air on the unit. I recommend your cover the opening with some plumber's putty to see if it helps.Adjust the temperature on your ecobee smart thermostat. ecobee smart thermostats balance comfort and savings like magic by adjusting your temperature automatically—but you can also change it manually on the thermostat itself or in our intuitive app. Get to know your Smart Thermostat >.Stage one will run for 10 minutes before stage 2 kicks in if it ever does. Reverse staging only works if stage 2 actually kicks on because then that last half degree is handled by stage one and stage two cuts out. There are a couple of good YouTube videos on it and they recommend the temp differential to be 1° but the stage to delta to be 2 ...support.ecobee.comThe furnace would start its cycle with the fan on, then it would stop and start when the furnace was heated up. Also Im not sure if I ever got back with you. I was having trouble connecting ecobee to beestat.io. Turned out I had to be logged off of ecobee before beestat.io could be authorized.I know that my AC uses about 2.75kW/hr, so if I can find an easy way to view AC runtime for various periods of time, then I can get a better picture of AC costs. I just installed ecobee two days ago, so I'm still learning. I also have beestats set up, but I cannot find runtime info in beestats either. UPDATE: I think I found it in both the ...raise the heat differential as mentioned, as well set the minimum fan run time, try 30 minutes 1st. there is also a setting for fan run time after heat, set to 3 minutes from the auto heat disippation runtime under threashholds on ecobee This should help from the calls the stage 2 heating, and make your house evened out heatingOn the other hand, if your furnace doesn't do this (my neighbor has a Trane that doesn't), then the fan has to controlled by the thermostat - otherwise heat generated by the furnace will not be distributed. There's a simple way to test this. Short the R and W wires. If the blower comes on, then you know that the furnace controls the fan when ...The following system won to support the ecobee variable speed feature. Dual-transformer systems; Note: Since thermostats require Rc and Rh wires and the ecobee Power Extender Kit, which are not compatible. Fan-coil units that need to be fixed with the G1, G2, and G3; Every AC system that comes with a multi-speed fanExpand user menu Open settings menu. Log In / Sign UpIn an international where vitality efficiency is popping into more and more main, many folks are turning to know-how and innovative tips to turn into moreThe fan capabilities object represents the set of fan capabilities the thermostat has. For example, this can include the available fan speed options. PropertiesThe compressor min runtime doesn't apply when you make changes to the ecobee; either changing the setpoint or the mode. I guess they figured if you adjust the setpoint it's because you're too hot/cold, so it applies the new settings immediately. If you had let it run without manually adjusting the settings, it would have enforced the minimum ...In the automation, I have a kluge that runs the condition any time the spread is > 2.8 degrees, but I actually only set the fan runtime if the spread is >= 3.0 degrees. This is so that there is a chance for the automation to set the fan runtime to zero. Otherwise I’d need 2 automations, one to turn the fan on and one to turn it off.Went into the office last night, AC was set at 90F as I have it in the evenings to prevent it from running, ambient air was 72, fan came on for no apparent reason two hours later. Could not find anything in the settings to that would cause this function. (IDK how long it ran for.) Never happened prior to installing the Ecobee product. Any ideas ...Set your desired temperatures and fan runtime by selecting Vacation Settings. Then select Save. On the ecobee app. Tap on Home > Tap on Vacation, then tap on Set a vacation. Tap on Depart to set the start date and time. Tap on Return to set the end date and time. Set your desired temperatures and fan runtime by selecting Vacation Settings.Huh. I didn't realize this. I used to have a Nest and it performed as you expect. If you said 20 min/hour, and the system didn't cycle at all, it would run the fan 20 mins every hour. If the system cycled (heat or air), that cycle time was counted as part of the 20 mins. Hopefully Ecobee devs make this an option.To begin, go to Ecobee's website on any computer and click "Login" at the top. Unfortunately, the only way to view your Ecobee's usage history and reports is through the web interface. Enter in your username and password, and then click "Sign In". Click on "Home IQ". If you see the below screen, it means that your Ecobee hasn't been in use for ...At 20F degrees, the heat pump is struggling to keep up...this is when heat pumps are least efficient. So, in most cases, the installer will include heat strips which are expensive to run but are a 2nd stage, only used when the heat pump cannot keep up. This is typically a set # of degrees that the room temp is less than the set temp, it will ...If Stage 1 can maintain the temp between 75.1 and 75.9 it will run for the Max runtime of 40 minutes and then kick in stage 2 to finish off the cooling cycle ... This is an installation issue, not an ecobee issue. The ecobee doesn't control the fan speed and is not to blame for humidity issues during stage 1 operation. All the ecobee can do is ...Can someone provide the location of the timer on the ecobee that is not on the mobile app. ... you are describing automatic minimum runtime for a fan, not manual activation of the fan. My question was answered by antlestxp. The newly implemented feature is not available in the app, but can be accessed on the thermostat. ...When your Ecobee smart thermostat reports that the fan is running but no equipment is detected, it essentially indicates a mismatch between what the thermostat perceives and the actual operation of your HVAC (Heating, Ventilation, and Air Conditioning) system. In simpler terms, your thermostat thinks the HVAC equipment should be running, but it ...Setting fan runtime is useful for circulating air throughout the house outside of heating or cooling cycles. The range that you can select for fan runtime on the Ecobee is between 0 to 55 minutes, and increases in 5-minute increments. Depending on how long you set the fan runtime for, there Ecobee will respond slightly different.I installed an Ecobee smart thermostat. One of the options is to set the fan to run a certain amount of time, for instance 20min/per hour. So after 15 min, it will run for 5 min, wait another 15 min, run for 5 min and so on. It somehow also calculates that runtime in when the furnace is running.When the temperature outdoors changes where the AC total daily runtime is less than 1 hour or two you could use a 15 minute minimum runtime. But, keep in mind that ecobee uses two 7.5 minute runtimes to make up that 15 minutes. If you set it for 20 or more ecobee divides by 4 so for 20 it would run it for four 5 minute runtimes.Trying to figure out a way to have the fan only kick on and run for a certain period of time. With it getting cooler there are plenty of times that…... fan coil units with up to 3 fan speeds. One 1 ... ² Based on internal measurements of thermostat runtime data. ... ecobee3 lite owners can take advantage of eco+ ...For my setup I chose to let Ecobee control the furnace fan and runtimes. Set it to ECOBEE in this area. MAIN MENU > SETTINGS > INSTALLATION SETTINGS > EQUIPMENT > FURNACE > FAN CONTROL IN HEAT MODE. The following is a personal preference setting MAIN MENU > SYSTEM > FAN. This is to set the FAN MINIMUM RUN TIME. You can set how long the furnace ...Why does air cool down when pushed around by an electric fan? You would think that air molecules in motion would be creating friction, and therefore increasing the ambient temperat...I just purchased Ecobee for my home. Fan is set as Auto to run min 15 mins / hr. Is it normal for the fan kick in 15 mins / hr all day long, ... Under System → Accessories → Fan → Fan Runtime, set it to 0 min/hr. But doing so might make your AC work harder than it …Our nest at the old house would run the fan on low for 15 minutes every hour between 8am and 8pm. You could select the run time and the hour window to suit your needs. 19 votes, 12 comments. I work from home now and the office is in the room directly above the furnace. I have our fan set to 20 minutes an hour and….fan: If the fan is currently on or off: on / off. climate_mode: This is the climate mode that is active, or would be active if no override is active. equipment_running: This is a comma-separated list of equipment that is currently running. fan_min_on_time: The minimum amount of time (in minutes) that the fan will run per hour.First, set your Ecobee Thermostat to Auto mode: Open the menu on your thermostat. Select “ Settings .”. Choose “ Installation Settings .”. Select “ Thresholds .”. Enable “ Auto Heat .”. Now, you can use the slider on the main display screen to change your heat set point. To change the heat set point in the Ecobee app:I have an Ecobee 3 in a rental unit (nicer and simpler user UI than CT100). One feature that we like about it is being able to set a minimum fan runtime so during those days were the temperature doesn’t kick off the HVAC you can still move/filter the air.Check Your Minimum Fan Runtime. Another reason your Ecobee Thermostat fan won’t turn off is the runtime setting. The runtime feature allows you to set the time each hour your home’s fan will run. This is useful to circulate the air inside your living space. The minimum fan runtime only applies when the fan setting is on Auto.System Monitor is used to view detailed graphs depicting your thermostat's runtime data. Access Sytem Monitor by signing in to ecobee.com, opening the Home IQ portal, and …For all of us that have an Ecobee, we know that they are smart thermostats. However, we probably don’t know just how smart they are without getting into someI'd like to run it 60m/hour but it's hard on the hydro bill, so I try to do at least 30m/hour. The one thing I liked about Nest, when it had a working API before Google shoved us all out in the cold (which was one of the biggest things that sent me to Ecobee) was that I could directly control the fan with software.In an international where vitality efficiency is popping into more and more main, many folks are turning to know-how and innovative tips to turn into moreAutomatic versus Manual Threshold Staging: By default, ecobee thermostats will have the Configure Staging option set to Automatically. In this mode, the thermostat uses smart algorithms to determine heating/cooling calls, staging, and fan runtime. If you prefer more control, you can switch to configure staging Manually, which allows fine-tuning ...Although you cannot connect your Ecobee thermostat to a Vivint system, two types of smart thermostats are compatible with the Vivint system. These include: Vivint Thermostat. Nest Thermostat. The Vivint Thermostat is a good alternative to Ecobee, as it offers many of the same features. These include temperature control and lighting control.For all of us that have an Ecobee, we know that they are smart thermostats. However, we probably don't know just how smart they are without getting into some advanced settings like fan runtime.Ecobee Smart Thermostats have advanced features allowing users to control number of minutes that the fan ca...Premium quality - Perfect for customers who want to catch all the particles they can, even some of the smallest ones like cooking oil and cigarette smoke. MERV 13 level of filtration. The static pressure drop ratings in H2O are 0.122 for Basic, 0.181 for Deluxe, and 0.264 for Premium. ecobee Air filters does not currently provide accordion ...A subreddit for ecobee and all their smart home products. ... Are there cases when setting the fan runtime per hour makes sense? I currently have it set to 5 minutes/hour to help even out the heat in the house during winter. But in the summer, it's running against a humidified evap coil (outside cooling runs) ...ecobee calculates energy savings by correlating how long your heating and cooling equipment run to local weather conditions. Energy savings are calculated relative to a commonly used desired temperature of 72°F (22°C). We calculate your estimated cost savings based on your equipment's runtime savings, the average electricity rate in your ...A subreddit for ecobee and all their smart home products. ... Ecobee calling for fan even though min runtime/hour set to 0 minutes. Unit is currently in cooling mode. A/C hasn’t run since 4:55AM, yet fan has run at 5:24-5:31, 5:54-6:01, and 6:24-6:31. I don’t want the fan blowing air over a wet coil and humidifying the house.Jun 21, 2017 · From the Ecobee website: The Minimum Fan Runtime that you set will be spread out over an hour if it is set for 15 minutes or less. For example, if it is set for 10 minutes in the hour, it will run for 2:30s every 15 minutes over an hour. If the Minimum Fan Runtime is set for 20 minutes or higher, the fan will run in 4 equal parts over the hour.I have a VB script in Homeseer that calculates the standard deviation across my 4 Ecobee temp sensors every 15 minutes. If the standard deviation between all the sensors is less than 1 deg, then set Ecobee minimum fan runtime to 5 mins/hr. If between 1.1 and 1.7 deg, then run fan for 20 mins/hr. If over 1.8, then run fan full time.Ecobee EB-STATE3LT-02 ecobee3 lite Smart Thermostat, 2nd gen - Use Manual - Use Guide PDF. Documents: Go to download! User Manual. ... Auto: Enable fan when the system is actively heating or cooling your home, or to satisfy the Minimum Fan Runtime setting (page 12). On Thermostat and Mobile: Select Main Menu > Quick Changes > Fan. On Web:The Ecobee Power Extender Kit works by connecting to your home's existing thermostat wires to create a complete circuit; this provides continuous 24-volt AC power to your thermostat for homes that don't have a C wire. Install the PEK on the HVAC system's control board. Ecobee smart thermostats come with a Power Extender Kit included free ...Schedule a vacation. On the thermostat. Go to Main Menu > General > Vacation, then select the Plus icon. Select I Depart to set the start date and time. Select I Return to set the end date and time. Set your desired temperatures and fan runtime by selecting Vacation Settings. Then select Save.You can change the HVAC system settings directly on the thermostat's home screen or through the ecobee app. On the thermostat. Go to the Main Screen > System Mode then, choose between Heat, Cool, Auxiliary or Off. On the ecobee app. Tap on the thermostat card > Go to the General > System > HVAC Mode then, choose between Heat, Cool, Auxiliary ...Fan run time on ecobee is a property that gives you the liberty to select the ideal running time of the fan in an hour. It is applicable when you’re interested in air circulation outside the typical cooling and heating cycles. It saves you from manually switching the fan on and off as the temperature changes … See moreThe last three 5 minute HVAC Runtime values in seconds (0-300 seconds) per interval. This value corresponds to the cooling stage 2. fan: Integer[] yes: no: The last three 5 minute fan Runtime values in seconds (0-300 seconds) per interval. humidifier: Integer[] yes: no: The last three 5 minute humidifier Runtime values in seconds (0-300 seconds ...You can see if your ecobee thermostat is currently running the equipment in two different ways: 1. Confirming the ecobee is active using System Mode icons. On the Thermostat, the System Mode icon will appear at the top of the Home screen. Depending on your thermostat model, when equipment is running, the icon will either be colored or there ...31 May 2015 ... I can tell the Nest, run my fan for 30min every hour on a schedule. This actually is the biggest money saver as what does is even out the ...The setting which is accessible from the ecobee iOS/Android app is a minimum run-time for the blower fan per hour to normalize temperatures throughout the conditioned space. 5-10 min/hr can be helpful in some situations ... then the fan has met that runtime and wont run anymore that hour. If theres an hour where your system only called heat ...The ecobee API provides an http-based interface for control and access to the ecobee thermostats. Integrators will be allowed to read, update and poll information about their thermostat (s). ecobee aims to be backward compatible with previous versions of the API and to protect implementations from breaking when new features or changes are ...HomeIQ calculates your energy rating based on insights from three key metrics: Your ecobee saved you: This percentage value reflects your equipment runtime and temperature setbacks over the past month. By analyzing these factors, we create a model to determine the savings achieved compared to a constant 72°F thermostat setting. Your …first pic is old ihermostats, second is new ecobee. I installed it yesterday, the fan keeps running. for settings, I set Fan runtime for auto mode to 0 min/hr, and fan is on auto mode. the Ecobee shows "no equipment running". but the fan runs all the time. did I install the ecobee in a wrong way? for old thermostats, the fan stops after heat or cool when the …LookDamnBusy. • 2 yr. ago. You can take the ecobee completely out of the loop by removing it off the wall, and connecting the fan wire to the R terminal and seeing if it blows the same slow speed you are thinking it is doing. That's all the any thermostat is doing when it turns on the fan anyway, is making that connection.Overview. This screen gives you an overview of the previous month's HomeIQ reports. HomeIQ reports for the previous month are typically ready within 14 days of the current month. Select the relevant tile to bring up the current and historical reports or the System Monitor tile to view detailed graphs depicting your thermostat's runtime.If Configure Staging is set to Automatically. When your thermostat's Configure Staging setting is set to Automatically, you can adjust the Aux Savings Optimization value to lower aux heat usage. 2°F / 1.1°C - sacrifice savings for comfort. 2°F / 1.1°C - sacrifice savings for comfort. 2.3°F / 1.3°C - sacrifice a bit of savings for comfort.The fan is set to run for 5 minutes after the HVAC turns off. I think that is the default setting. Which, it does do, because I've checked the screen when I hear the AC turn off and the fan is still going. For some reason when the dedicated fan wire was connected, it would just never shut off the fan.The following system won to support the ecobee variable speed feature. Dual-transformer systems; Note: Since thermostats require Rc and Rh wires and the ecobee Power Extender Kit, which are not compatible. Fan-coil units that need to be fixed with the G1, G2, and G3; Every AC system that comes with a multi-speed fanThe minimum fan run time for the Ecobee Thermostat depends on what environment you live in and what temperature you prefer to keep your house at. However, the recommended time to run the Ecobee Thermostat is between five and 20 minutes. Getting the Most Out of Ecobee Sensors You can pair up to 32 room sensors to your entire ecobee system and ...Runtime Report. This menu displays your thermostat's estimated savings compared to the 72°F/22°C benchmark. Good to know: To generate a report, there must be at least 5 …You can set the minimum compressor run but the maximum is determined the the desired temperature. Generally you do not want to run the AC for short pulses because it takes about 10 min to reach peak efficiency and then you want decent on-time to properly dehumidify the air. Without a set point to tell it when to turn on, you'll be in manual ...This looks at the reported current operation mode. Any value of this new sensor of 1 or more indicates the fan is running. 0 indicates the entire HVAC is idle. 1 indicates only the fan is running (fan on, in hold) 2 indicates it's heating. 3 indicates it's cooling. This works in all control modes (if the ecobee was being controlled locally, by ...There is only one file (pyecobee / __init__.py) you'll need to change. First, create a new branch to hold your changes (shown in the the code snippet below). Then this GitHub commit diff will show you the changes you need to make. QUICK NOTE: the diff (on line 289) shows removing a hold_type variable assignment.Ex: Hey Siri, Turn on the ecobee fan. It stops the current schedule, runs the fan immediately for the specified amount of time (based on per hour setting) BUT runs it consecutively over the next hour instead of breaking it up then switches back to the proper schedule / fan setting at the end of the hour. 2. Optional Smart Fan control would be nice.Problem. I noticed my fan is running all day and night. We did have a furnace issue a few months ago and the HVAC guy ended up hooking up the G wire to the thermostat while he was there so I could control the furnace fan. I checked my ecobee settings and the fan is set to auto at a minimum of 0 min/hr. Out of curiosity, I exported the Ecobee ...Steps to Fix Ecobee Not Turning On AC: Check Thermostat Settings: Ensure the Ecobee thermostat is set to the cooling mode and the desired temperature. Inspect Wiring: Examine the wiring connections, confirming they are properly seated and undamaged. Power Source: Verify that power reaches the thermostat and the HVAC system.The blower motor is a three-speed motor, I have it wired to use the lowest speed during cooling (so air drawn across the evaporator coils has the best chance of dehumidifying). Under these conditions, the blower motor pulls ~650 watts/hr when it is running. So if it ran for 10 minutes per hour, it would draw about 2.7 kWh per day.Heat/Cool Dissipation Time is the setting where ecobee controls the fan runtime after your HVAC reaches the right temperature.. In its factory Auto mode, your fan will run for 30-45 seconds after it meets your heating or cooling requirements.. The ecobee offers this function to ensure that all the heated or cooled air is used from inside the ducts and moved into your living space before the ...Power-cycle your ecobee thermostat by removing it from the wall and leaving it off for about two minutes. Place your ecobee thermostat back on the wall and wait for it to power up. Re-insert the battery into your Room Sensor and hold it close to your ecobee. You should see a prompt to pair your Room Sensor on your ecobee's screen.So I thought maybe I should at least run the fan. I have always had the minimum runtime set to 0, but now I have changed it to 10 minutes per hour. I would honestly prefer if it could just run now and again every couple of hours, but that doesn't seem to be an option that the ecobee provides, unless I want to do it manually.Free Cooling Max Outdoor Humidity : This prevents Free Cooling from running when the outdoor humidity is too high. By default, this option is disabled. If you set this to Auto, your thermostat will determine the maximum allowed humidity level based on the temperature. Indoor/Outdoor Temperature Delta : The difference between indoor and outdoor ...Similar issue here. Normally I have the fan set to auto / 5 min per hour. I have my Hubitat set the fan to "on" whenever a bathroom vanity light is on to circulate air when we use the shower. (plenty of air supply but no suitable vent fan) The Hubitat is programmed to set the furnace fan to auto when the lights are turned off. Doesn't work.API USAGE LIMITS. Use the Thermostat Summary (Polling) request to determine if the Runtime Revision value has changed before making repeated requests for runtime reports.; DO NOT request report data at an interval quicker than once every 15 minutes, which is the shortest interval at which report data can change.There may also be a delay …. If Configure Staging is set to AutomaticalDon’t need to use Auto and have it stop and start a My new system's fan runs at 38% in fan mode. about 45 watts. I set it to run continuously during my afternoon comfort setting. My opinion, if you have an older single speed fan, use the minutes per hour option. If you have a newer variable speed fan, let it run continuously during the comfort settings where you think you need it.Fan runtime with of Ecobee thermostat can a setting that allows you to choose how many minutes per hour you want the fan in your HVAC structure to run, regardless of heating or cooling cycles. Setting electric runtime is useful for circulating air throughout the house outside of heating or cooling cycles. The ecobee Energy Management System (EMS I have an issue with the fan on my furnace, in which it sometimes will not turn on when asked. You can hear it attempt to kick in, but will not actually start. (this is a bigger issue, likely requiring a repair). The Ecobee Fan runtime obviously causes havoc with this, as it attempts to run 2-4 times per hour depending on the runtime set. Benefits of My Ecobee device vs. Hubitat's ecobee stock device...

Continue Reading