Synthes rfna inventory. 3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nons...

The Variable Angle LCP™ Curved Condylar Plate is a distal f

The number of homes available for sale is finally improving, providing some hope for buyers burned out by an extremely competitive market. By clicking "TRY IT", I agree to receive ...Educational resources from DePuy Synthes are designed to help you educate patients easily and efficiently, in your office and in your community, on osteoarthritis and joint replacement. These resources – including patient education brochures, anatomical posters, and more – have been designed to help your patients better understand their ...9. DePuy Synthes Validation Lab Questionnaire Results for Femoral Recon Nail System. 12/06/2017. Windchill Document #0000266807. 10. DePuy Synthes Shared …Instructions for Use Retrograde Femoral Nail Advanced ... Nails.Synthes Rafn Nail Inventory Choose Form 2020; Get Synthes Rafn Nail Your Control Application 2020-2023 Obtain form . How It Works. Open form follow the instructions. Simply sign the form with your finger . Send filled & signed form or save . rfna inventory rating ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ 4.8 ...The UNIUM Small Bone Power Tool System can handle trauma, sports medicine, spine, and cardiothoracic procedures and features an ergonomic, reliable, and efficient designInventory Control Form FRN-ADVANCED™ – Piriformis Fossa Femoral Recon Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): FRN-ADVANCED™ Femoral Recon Nail System, Piriformis Fossa, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) 04.033.928S 04.033.929S 280 04.033.930S 04.033.931S 300synthes.vo.llnwd.netHandy tips for filling out Synthes rafn nail inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with airSlate SignNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Synthes frn inventory control form online, e-sign them, and …The Modular Mini Fragment LCP™ System is an instrument and implant module set intended for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. Product Specifications. How to Use This Product.TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) – Screw Only fi Surgical Technique 3 The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.If you have a specific Medical Information Request, please use this Medical Information Request form instead of this form, so that your request can be correctly managed directly by our Medical Affairs team. The personal data collected on this form, will be used to validate your request & also manage our relationship with you.The RFN-Advanced is a retrograde nailing system for distal femoral fractures, with a locking attachment washer for enhanced fixation. It is approved by AO Technical Commission and AO Foundation, and has details, instruments and videos available.Some advantages of inventory management include ensuring that a business does not spend money on unnecessary product orders and tracking which products are selling and which are no...8 DePuy Synthes Surgical Technique MatrixMIDFACE™ Plate and Screw System Intended Uses, Indications, Contraindications Intended Use MatrixMIDFACE™ Plate and Screw System is intended. for use in trauma repair and reconstruction of the craniomaxillofacial skeleton. Indications. DePuy Synthes MatrixMIDFACE Plating System is intendedU.S. stocks traded lower midway through trading, with the Dow Jones dropping around 100 points on Wednesday The Dow traded down 0.32% to 31,687.6... U.S. stocks traded lower midwa...4 DePuy Synthes 1.5 mm LCP® Modular Mini Fragment System Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, whichCanulación de todos los clavos para la introducción guiada en la técnica con fresado y sin fresado. Clavos con una gran variedad de diámetros, de 9 a 15 mm, y longitudes de 160 a 480 mm. Configuración versátil para el bloqueo para el bloqueo estático, dinámico, estándar y de hoja espiral. retrógrado.4 DePuy Synthes 1.5 mm LCP® Modular Mini Fragment System Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, whichDESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.Trauma & Extremities. Our Trauma & Extremities portfolio offers comprehensive solutions for the treatment of fractures, deformities, and other orthopaedic traumas. Our wide range of surgical instruments and fixation products are designed to provide solutions tailored to the diverse needs of orthopaedic professionals and patients.SYNTHES GMBH RFNA/ 10MM/ 360MM/ STANDARD BEND/ STER; ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES: Back to Search Results: Catalog Number 04.233.036S: Device Problem Adverse Event Without Identified Device or Use Problem (2993) Patient Problem Non-union Bone Fracture (2369)4 Surgical Technique ®• TFN-ADVANCED Proximal Femoral Nailing System (TFNA) The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.Position the image intensifier as for an AP view of the proximal femur. Using long forceps, hold the ruler paral-lel to the femur on the lateral side of the upper leg. Position the ruler such that the end is located at or just below the level of the tip of the greater trochanter. Mark the skin on the lateral side.Nail Design. Cannulated nails (from diameter 8 mm to diameter 13 mm) for reamed or unreamed techniques, enabling nail insertion over guide wire. The 2.5 mm or 3.0 mm ball tipped guide wires may be removed through …2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.Learn the Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) surgical technique with step by step instructions on OrthOracle. Our e-learning platform contains high resolution images and a certified CME of the Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) …Synthes guarantees the compatibil-ity of its different original implants and/or instruments. The product-specific instructions for use as described by Synthes must be followed. It is not advisable to mix Synthes products with those of different manufacturers, since designs, materials, mechanics, and construction are not harmonized.The new RFN-Advanced (RFN-A) Retrograde Femoral Nailing System was developed to address these issues. The Locking Attachment Washer (LAW) can be regarded as the most important innovation of the RFN-A System. The LAW concept allows to connect an anatomically shaped 6-hole plate (the locking attachment washer) at the lateral femoral epicondyle to ...6 DePuy Synthes Titanium Cannulated Lateral Entry Femoral Recon Nail Surgical Technique Clinical Cases Case 1–Standard locking • 85-year-old female • Isolated femoral shaft fracture (AO 32-A1.2) For simple shaft fractures, two proximal and two distal ML locking screws are normally sufficient to stabilize the fracture.Inventory Control Form LCP Dynamic Helical Hip System (DHHS) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5047-E 2/11 LCP DHHS Compression Screw 211.890 4.5 mm Cortex Screws, self-tapping LENGTH 214.828 28 …Journal of Orthopaedic Trauma, Vol 18(6):361–368 lbid. Synthes TFN – Titanium Trochanteric Fixation Nail System Technique Guide... Page 7 Lag Screw 0.5 (112 lbs) 1000 10,000 100,000 1,000,000 10,000,000 Cycles Test conducted at Legacy Research and Technology Center, Portland, OR. Test conducted at Synthes Mechanical Testing Lab, …Inventory Control Form TN-ADVANCED™ Tibial Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TN-ADVANCED™ Tibial Nailing System Ø 8 mm, Sterile Right Part # Length (mm) 04.043.005S 255 mm 04.043.010S 270 mm 04.043.015S 285 mm 04.043.020S 300 mm 04.043.025S 315 mm 04.043.030S 330 mm 04.043.035S 345 mmSynthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...In today’s fast-paced business environment, effective inventory management is crucial for maintaining a smooth workflow and maximizing profitability. One key tool that can streamli...The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)This video features Tyson from Depuy Synthes teaching you the steps for insertion of a TFNA femoral nail.The RFN-Advanced is a retrograde nailing system for distal femoral fractures, with a locking attachment washer for enhanced fixation. It is approved by AO Technical Commission and AO Foundation, and has details, instruments and videos available.Inventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, …While retail work is the world’s largest employer, and one with more than 1.3 million in the United States alone, it’s an industry riddled with crummy jobs—low-pay, part-time, ever...Inventory Control Form 3.5/4.5 MM VA LCP™ PERIPROSTHETIC PROXIMAL FEMUR PLATING SYSTEM 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, LEFT, SSt 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, RIGHT, SSt Size 02.221.101 SMALL 02.221.103 LARGE Size 02.221.100 SMALL 02.221.102 LARGE02.118.408 7 holes, right 02.118.409 7 holes, left. 2.7 mm Variable Angle LCP Distal Tibia T-Plates. 02.118.306 4 holes 02.118.307 6 holes. Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Inventory Control Form. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System.The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)DePuy Synthes MatrixRIB straight plates are indicated for the fixation, stabilization and reconstruction of: • Rib and sternum fractures, fusions, osteotomies, and/or resections, including spanning gaps and/or defects • Pectus Excavatum, Pectus Carinatum, and other chest wall deformities DePuy Synthes MatrixRIB sternal plates, 2.8 mm thickness,9. DePuy Synthes Validation Lab Questionnaire Results for Femoral Recon Nail System. 12/06/2017. Windchill Document #0000266807. 10. DePuy Synthes Shared Instrumentation TFNA-FRN A.7. 2/8/2018. Windchill Document #0000273347. 11. DePuy Synthes Design Verification Report – T115 FRNProtection Tube – Bending Resistance. 10/13/2017.SE_793149 AA page 2 / 5 Instructions for Use Retrograde Femoral Nail Advanced Devices in scope Retrograde Femoral Nail Advanced, 5 Degree Bend LengthThis site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only. Not all products are currently available in all markets. The ...About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy Synthes and has features that allow surgeons to address proximal femur fractures. The system includes: Long Nails – Diameters: 9-12, & 14 mm. Lengths ranging from: 260 – 480 mm. Short Nails – Diameters: 9-12 mm.Synthes Flexible Reamer Set for Intramedullary Nails (150.060) Instrumentation Catalog # Description 351.05 Tissue Protector 351.15 Flexible Shaft Handle, Quick Coupling, Cannulated 351.717 Depth Gauge 351.719 Depth Gauge Extension Tube Holding Forceps 351.782 Holding Forceps 351.783 Removal Tool, for use with Medullary Reaming HeadsPatient information: DePuy Synthes (USA) To order: (800) 227-6633 DePuy Synthes (Canada), Ltd. To order: (800) 668-1119 InvenTory ConTrol Form Titanium MatrixNEUROTM implants Titanium MatrixNEUROTM Screws Self-Drilling PaCkage oF 20 04.503.103.20 3 mm 04.503.104.20 4 mm 04.503.105.20 5 mm PaCkage oF 1 …Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°Inventory Control Form Small Fragment Locking Compression Plate (LCP™) System 204.848 3.5 mm Locking Screws, self-tapping, with StarDrive™ Recess Length 202.830 30 mm 202.832202.812 32 mm 202.834 34 mm 202.816 202.836 36 mm 202.818 202.838 38 mm 202.840202.820 40 mm 202.845 45 mm 202.850 50 mm 202.826 202.855 55 mm …The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10175-C 5/11 2.4 mm/2.7 mm VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm VA-LCP Forefoot/Midfoot Plating System 02.211.230 0° right 02.211.231 0° left 02.211.232 5 ...Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam …The Variable Angle LCP™ Curved Condylar Plate is a distal femur implant designed to address multiple patient anatomies, fracture patterns and surgical situations including supracondylar, intra-articular and extra-articular condylar fractures, and periprosthetic fractures. Product Specifications. How to Use This Product.While retail work is the world’s largest employer, and one with more than 1.3 million in the United States alone, it’s an industry riddled with crummy jobs—low-pay, part-time, ever...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010by the AO and DePuy Synthes and belong still to sur - geons basic armatorium used for fracture treatment, revision surgery and correction osteotomies. Due to their fixed-angle shape, successful application needs planning, concise orientation in all planes (AP and lateral views, rotation) and preparation of the channel for the blade. IntroductionEnsure the details you add to the Synthes Rafn Nail Inventory Control Form is updated and accurate. Add the date to the document using the Date function. Select the Sign button and make a signature. You can find 3 available alternatives; typing, drawing, or uploading one. Re-check each and every field has been filled in properly.8 DePuy Synthes Surgical Technique MatrixMIDFACE™ Plate and Screw System Intended Uses, Indications, Contraindications Intended Use MatrixMIDFACE™ Plate and Screw System is intended. for use in trauma repair and reconstruction of the craniomaxillofacial skeleton. Indications. DePuy Synthes MatrixMIDFACE Plating System is intended02.130.150, 02.130.150S, 02.130.151... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle Locking Hand System consists of 40 different basic and specialty plates, available in stainless steel and titanium, including fragment-specific plates designed for lateral and dorsal application in fracture repair and deformity correction.Fill synthes rfna inventory : Try Risk Free. Rate free synthes tfn inventory form. 4.4. Satisfied. 37 Votes. For pdfFiller’s FAQs. Below is a list of the most ...synthes.vo.llnwd.netInventory Control Form 2.0 mm Quick Insertion Screw (QIS) and 2.0, 2.5, 3.0, 3.5, 4.0 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 ...by the AO and DePuy Synthes and belong still to sur - geons basic armatorium used for fracture treatment, revision surgery and correction osteotomies. Due to their fixed-angle shape, successful application needs planning, concise orientation in all planes (AP and lateral views, rotation) and preparation of the channel for the blade. IntroductionDePuy Synthes RFNA Nail/LAW Static Construct Design Verification . Report. 04/28/2020. Windchill Document #0000293480* 7.The tips below will help you complete Synthes Tfn Inventory easily and quickly: Open the template in our feature-rich online editing tool by clicking on Get form. Fill out the requested fields that are yellow-colored. Press the green arrow with the inscription Next to move on from one field to another. Use the e-signature solution to add an ...SE_793148 AC page 2 / 7 Instructions for Use TFNA, 9 mm, long Right Left Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2933-M 12/12 Inventory Control Form 4.5 mm, 6.5 mm, 7.0 mm and 7.3 mm Cannulated Screws 4.5 mm Cannulated Screws, partially threaded LENGTH LENGTH 214.520 20 mm 214.522 22 mm 214.524 …The Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.In today’s fast-paced business environment, effective inventory management is crucial for success. Properly managing your inventory not only ensures that you have the right product...of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contact3.1. Total numbers. In total, 127 fixations using the TFNA for proximal femur fractures were performed at our unit between June 1, 2017 and December 31, 2020 (42 months). 107 (84%) were fragility fractures, 14 (11%) were pathological fractures secondary to malignancy and six (5%) occurred following high energy trauma.Inventory Control Form Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaftAbout This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy Synthes and has features that allow surgeons to address proximal femur fractures. The system includes: Long Nails – Diameters: 9-12, & 14 mm. Lengths ranging from: 260 – 480 mm. Short Nails – Diameters: 9-12 mm.Complete Synthes Rafn Nail Inventory Control Form 2020-2023 view with USAGE Legal Forms. Easily fill out PDF blank, delete, and sign them. Storage or ... Tips on instructions to fill out, edit and sign Synthes rfna inventory control form …About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate – Low Bend. 4.5 mm LCP Proximal Tibia Plate.In any business, effective inventory management is crucial for success. It involves the process of overseeing and controlling the flow of goods from the moment they are acquired to...Position the image intensifier as for an AP view of the proximal femur. Using long forceps, hold the ruler paral-lel to the femur on the lateral side of the upper leg. Position the ruler such that the end is located at or just below the level of the tip of the greater trochanter. Mark the skin on the lateral side.The Expert Tibial Nail permits an intra medullary approach for the fixation of proximal, shaft and distal fractures of the tibia. The system consists of a series of cannulated nails, can-nulated end caps, dual core locking screws and standard locking screws. All of the implants are made of titanium alloy (TAN*).Inventory Control Form 3.5/4.5 MM VA LCP™ PERIPROSTHETIC PROXIMAL FEMUR PLATING SYSTEM 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, LEFT, SSt 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, RIGHT, SSt Size 02.221.101 SMALL 02.221.103 LARGE Size 02.221.100 SMALL 02.221.102 …. The Variable Angle LCP™ Curved Condylar Plate Variable Angle LCP™ Elbow System. Product Codes: 02.10 Inventory Control Form 3.5/4.5 MM VA LCP™ PERIPROSTHETIC PROXIMAL FEMUR PLATING SYSTEM 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, LEFT, SSt 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, RIGHT, SSt Size 02.221.101 SMALL 02.221.103 LARGE Size 02.221.100 SMALL 02.221.102 LARGESome devices listed in this Inventory Control Form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.0 mm Sternal Screws, self-drilling (5/pkg) 04.501.110.05 10 mm 04.501.112.05 12 mm 04.501.114.05 14 mm LENGTH Some devices listed in this Inventory Control Form m Inventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, … 2 DePuy Synthes 4.0 mm Cannulated Screws...

Continue Reading