Alltrax controller fault codes. installing an Alltrax Controller. That is the stock controller’s progr...

Call Alltrax Technical Support to see if we have a controller for your

This manual shows how to monitor and handle major and minor controller faults. The manual also provides lists of major, minor, and I/O fault codes to use to troubleshoot the system. This manual is one of a set of related manuals that show common procedures for programming and operating Logix 5000 controllers.RXV Controller Upgrade for 2012 and newer EZGo RXV Curtis Factory AC Controller with 35 pin connector. 24-72v. 650A Max Current for 30 seconds. Android and iPhone Apps (Coming Soon) ... Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected] Subscribe to Our Mailing List * indicates required.Page 29 BLINK CODES On power up, the controller will blink out a throttle code and then a Status or Error Code (see below) Throttle Type Codes: 1 Green LED Flash 2-wire 0-5k throttle 2 Green LED Flash 2-wire 5K-0 throttle 3 Green LED Flash 0-5V throttle 4 Green LED Flash EZGO ITS throttle...LED BLINK CODES 19 THROTTLE AND BRAKE CODES 19 ALARM CODES 20 CODE DEFINITIONS 21 WARRANTY STATEMENT 23. 4 AC OPERATORS MANUAL READ AND SAVE THESE INSTRUCTIONS ... the Alltrax controller. • Wear safety glasses. • Because hydrogen can build up due to gassing from the batteries, work in a well ventilated area. ...Model: DCX300 / DCX400 / DCX500 / DCX600. Type: Separately Excited (Shunt) DC motor controller. Battery Input Voltage: 24 – 48VDC Nominal, (60VDC max) Under voltage cutback: adjustable, 16-30 VDC. Over voltage shutdown: adjustable, 30-60 VDC (60VDC MAX) Field Current Limit: 30A (Programmed for Motor Field Excitation Curve) Operating Frequency ...Programming Cable for the Alltrax AXE and DCX Controllers USB-RS232. $23.00. No reviews yet Write a Review. On Back Order. Add to Wish List. SKU: ACC-USB-RS232. Availability: Out of Stock.EZGO 36 volt TXT PDS will not move forward or reverse. No clicking in controller. Have replaced curtis controller with AllTrax controller, still no movement. Replaced the key switch, forward / reverse … read moreDC motor controller for separately excited motors (not series) ABS + PC510 flame resistant thermal plastic enclosure. All copper heat sinks. Sealed epoxy UL-94-VO / 5VA flame rating (best in industry) Adjustable undervoltage cutback 16-30 VDC. Adjustable overvoltage shutdown 30-60 VDC. Operating Frequency: 18k Hz. Voltage drop @ 100amps: <.18V.The High Throttle Under range means it is significantly less than 10V. When pedal is pushed to floor, the voltage should decrease to 6V. Also, check the voltage between C4 Pins 1 & 2 on the controller with the C4 plug disconnected. Should be above 10V. Measure the voltage between the Black (C4 Pin-2) and White (C4 Pin-1) ITS wire at …Fault is displayed when both zero crosses are missing from the controller's input for 1.5 seconds or more. Could be a faulty excitation winding, zero cross circuit, loose wiring, or fieldAlltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected]This controller is programmable with the Curtis hand held programmer ***THIS CONTROLLER IS PROGRAMMED TO SPEED CODE 4. **** Curtis Controller 1515-5201 48 Volt Stock Replacement - Club Car Electric 2008 & Up ... Related Items. 250 amp fuse - for Alltrax controller - Yamaha Electric, Club Car Electric, $59.95 + Quick View 250 …I am assuming the controller is still fine and the SW 202 has gone bad (it is 5-6yrs old and gets used just about everyday playing golf) Any advice or help would be appreciated. ThanksBelow is the test procedures and results for all Alltrax controllers. OEM Curtis controller. tests attached below. Results should be as follows: DCS and Series carts have a signal range of 0.4-0.6v through 1.5-1.7v PDS carts have a signal range of 1.0v (+/- 0.3v) through 2.7v (+/- 0.5v) Throttle Voltage Check With Alltrax ControllersElectric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.XCT485001264/1268 36 or 48 Volt 500 Amp. $ 1,038.00 - $ 1,069.00. Curtis 1266 Replacement. Please call Alltrax technical support about your application for this controller at 541-476-3565.I had an issue and it turned out the Alltrax I had was set up for a Club Car instead of my EZGO. In the Alltrax App, when you are connected to the controller there was a bit of info about the throttle in the monitor section, I think. It's there somewhere if not in the 'monitor' tab. Anyway, it was visible there that it wasn't set up for my EZGO.Or the B- cable from the batteries to the controllers. 4 Flash. Open circuit fault. This is almost always caused by a loose connection. The first thing to do is connect the PcPak to the controller. This will give you a better explanation of the fault code. A 4 flash is almost always caused by a loose connection. If you have a 4 flash check the ...#golfcart #alltrax #controller Alltrax Controller Series Club Car - https://amzn.to/3XyeiJNMore Fentertainment Videos on Amazon - https://www.amazon.com/shop...One of the new features of the Alltrax SPM and XCT/SR controllers is ease of upgrading the controller’s firmware. When the controller is connected to Toolkit program, the program will check the version of controller firmware. If there is a new update available, the user will be prompted to upgrade the controller with a screen similar to this:Pack is at 48-49v -I have not charged it since returned home, plan on charging it tonight. Low voltage cut off is set around 20v so this is not the problem. I plugged the computer into the alltrax controller (sr48500) and it is communicating fine, responding to the throttle input, and everything else seems normal- NO ERROR CODES.13. Connect controller's F1 lug to motor's F1 terminal with orange cabled supplied in kit. 14. Connect controller's F2 lug to motor's F2 terminal using BLUE wire from kit. 15. Plug black control plug into the controller adaptor. 16. Double check all the wiring. (Doc100-065) 17. Set the Tow/Run switch in the "Run" position. 18.Group 2: 2-Green + Red alarm code is a condition that may inhibit or cause the controller to stop, but is not a hard fault, rather a condition that requires attention. Group 3: 3-Green + Red alarm code is an uncalibrated throttle, clear the throttle calibration and try again. The program may also have a fault or loaded or updated incorrectly.Alltrax code 2 red flashes? Electric EZGO. Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.I have an Alltrax SPM 72400 and was having troubles with it. All I get is a single blinking green LED light. The single blink indicates a 0-5k throttle. I tried to clear and reset the throttle but the controller LED …View all CO-SR-72400 : Controller Alltrax SR72400 Series/PM 72 volt 400 amp Peak Questions & Answers Related Product CO-SR-72400 : Controller Alltrax SR72400 Series/PM 72 volt 400 amp PeakItem #2 400 controller with HD 200 solenoid option. All around Campground & Neighborhood speed controller. 460 peak amp output, 36 or 48 volt operation, choose a 200 amp heavy duty solenoid with a free resistor, & diode. 200 amp HD solenoid is available in 36, 48, or 36/48 volts. Good for moderately bigger tires & rear seats on …Alltrax SR48400 Pdf User Manuals. View online or download Alltrax SR48400 Operator's Manual ... Brands; Alltrax Manuals; Controller; SR48400; Alltrax SR48400 Manuals. Manuals and User Guides for Alltrax SR48400. We have 1 Alltrax SR48400 manual available for free PDF download: Operator's Manual ... Blink Codes. 29. Warranty Statement. 31 ...As long as you have continuity between F1 & F2 and A1 & A2 you are ok, any other combination of continuity is bad (F1 or F2 to the Case, A1 or A2 to the case, or any F to A combination is bad) you can disconnect the motor from the controller (make sure the battery pack is disconnected first) add a jumper to the motor and hook up a 12 volt battery charger to the motor, as long as it spins, your ...2006: NCX - Alltrax Controller: STOCK Replacement for Shunt; Motors; 36-48VDC; 300-400Amp (Peak) Stock Fleet Grade; Non-Programmable; Solenoids, 200 & 400amp high performance rated; 24V, 36V, 48V, and 72VDC; SOL-200 with 800Amp Break; SOL-400 with 1000Amp Break; Use with Alltrax 500amp and higher controllers;voltage reducer Electric EZGO. Buggies Gone Wild Golf Cart Forum > Golf Cart Repair and Troubleshooting > Electric EZGO: Alltrax Blink Codes - maybe the controller's ok?Alltrax over current and shutdown 04 DS Last year I purchased a package from D&D motors that included a motor, wiring kit, HD solenoid and an Alltrax controller D&D 500 REGEN CC I0 5022 - TS which is a XCT48500-IQ.Controllers. DO NOT Use with Alltrax Controller Heavy Duty — Maximum performance, high speed, maximum torque, pulling loads, hilly terrain or Hunting Buggies. Performance 200 AMP (600amp Inrush) Use with 300 and 400 AMP Controllers Heavy Duty 200 AMP (800A surge) Use with 300 to 500 AMP Controllers Heavy Duty 400 AMP (1000A surge) …Alltrax fault code 5 Electric EZGO. Home: FAQ: Donate: Who's Online : Buggies Gone Wild Golf Cart Forum > Golf Cart Repair and Troubleshooting > Electric EZGO: Alltrax fault code 5 User Name: Remember Me? Password: Register: Golf Cart Pics: Site Sponsors: Members List: Calendar:Maytag washers are known for their durability and reliable performance. However, like any other appliance, they can occasionally encounter issues that may display error codes on th...Hardware: Use a STRAIGHT-THROUGH DB-9 pin / RS-232 serial interface cable to connect the controller to the PC. Alternatively use the preferred DB-9 pin RS-232 serial port to USB adapter. The DCX controller must be powered before the ControllerPRO program will have any effect. Before programming the DCX, READ THE SAFETY NOTES BELOW.This fault will automatically clear and the charger will restart charging when this problem is removed. Check the battery and connections to the battery. Check the nominal battery voltage. The first two digits of the four digit model name indicate the battery voltage the charger supports.Location: Charlotte, NC. Posts: 9,329. Re: Alltrax XCT 48400 Won't Power On. First, if You have a diode on the solenoid small posts, remove it (or at least make sure the polarity is correct). The original cart power 16ga red wire was "combo" crimped with the pack positive battery cable at the solenoid big post.Fault Code (cont.) Fault Description: Failure Code: Failure Description: PCM Fault Name: 3031: Electronic shift control commanded to actual position difference: 6: The device, calculation or process detected a fault. ESC_DesiredActualDiff: 3032: Electronic shift control loss of control: 6: The device, calculation or process detected a fault ...AllTrax 48600 code Electric EZGO. Home: FAQ: Donate: Who's Online : Buggies Gone Wild Golf Cart Forum > Golf Cart Repair and Troubleshooting > Electric EZGO: AllTrax 48600 code User Name: Remember Me? Password: Register: Golf Cart Pics: Site Sponsors: Members List: Calendar:ALLTRAX PRODUCTS SOLD TO CUSTOMER ARE INTENDED TO BE USED ONLY IN THE APPLICATION ... Thank you for using Alltrax controllers. Product Warran ty Statement for New Product . Title DOC120-049-C_WAR-Warranty-NEW-statement Author: Rcsuk Created Date: 12/2/2010 1:46:40 PMALLTRAX XCT500 36v Battery Under Voltage error code Electric EZGOXCT controllers have programming that is specific to the motor they are being paired with. Please provide us with the model of your motor in the Additional Information section at checkout. ... Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected] Subscribe to Our Mailing List * indicates ...Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected]Electric Club Car Electric DS, and Precedent golf carsPage 2- Cart won't go. Alltrax XCT controller Short Circuit/Output Fault Electric EZGOOver 200,000 Alltrax Electric Motor Controllers have shipped. Each unit reduces thousands of gas emissions each year. Alltrax XCT,NCT,SR, and SPM controllers can be programmed on your bench using a USB printer cable and our free Alltrax Toolkit software. The controller will power up via the USB cable so no external power supplies are needed.Alltrax controller throttle wire ebike razor contactor Motorcycle maintenance Motorcycle wiring diagram. Simple motorcycle wiring diagram for choppers and cafe racers - evan ... "Honda wiring motorcycle diagram cb200 electrical diagrams pdf cb200t manuals coil pole spark points ground manual codes fault Motorcycle wiring diagram software ...Repaired Controller + 1st eGator = 3,1 fault code. Running Controller + 1st eGator (again) = 3,1 fault code. Looking into the technical manual for the 1268 controller, they report the 3,1 fault code as: Fault {3,1} MAIN DRIVER OFF - Main contactor driver held high. Possible solutions: 1. Main contactor coil shorted. 2.Alltrax SR48300 Low voltage error in reverse Electric EZGOhave a 1995 ezgo TXT 36 volt with an Alltrax DCX 400 controller . The cart was giving me problems that pointed to bad batteries, so I upgraded and went with a set of lithium. ... DCX fault codes attached. Attached Images. DCX LED status codes.jpg (41.9 KB, 0 views) 07-01-2020, 08:53 AM #5: Sergio . Gone Wild . Join Date: Sep 2012. Location ...Electric Club Car Electric DS, and Precedent golf cars Electric DS, and Precedent golf cars600 amp alltrax error codes Electric EZGO. Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.Yesterday, I installed a new Alltrax SPM 48500 controller, heavy duty solenoid, heavy duty f/r switch, D&D 170-010-0002 speed and torque motor, and heavy duty cables. I powered the cart up after installing everything and the cart didn't move an inch. I looked at the controller and noticed the Led indicator light was blinking 2 green lights ...REDARC Brake Controller Flashing: Fault Codes. The Tow-Pro™ features sophisticated diagnostics to warn the operator of faults in the vehicle and trailer brake wiring. Wiring faults are indicated by a series of colour coded flash patterns on the Tow-Pro™ LED. ... Most fault codes can be cleared by unplugging the trailer for 1 minute then ...Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.The Alltrax Toolkit and SPM/XCT/SR controllers utilize a USB port for programming. There is no driver installation needed to get the computer to talk to the USB powered controllers. The required cable to program the controller is a USB A male (Computer side) to B female (Controller side). This is identical to most USB printer cables.prograMMing The ConTroLLer 30 BLink Codes 31 WarranTy sTaTeMenT 34 ... The fuse must be rated for pack voltage and fault current. 12 XCT OPERATORS MANUAL Wiring Controller Min. Wire AWG Standard Duty Min. Wire AWG ... system to allow for faster installation of Alltrax Controllers. Using the original mounting holes, the adapter plate bolts to ...Ezgo txt alltrax spm48500ez throttle type troubleshooting: Electric EZGO: Swapping Alltrax AXE 7245 450a for Alltrax SR 72500 500a: Electric EZGO: Troubleshooting Alltrax Controller on DS Series Cart: Electric Club Car: DCX 400 troubleshooting help: Electric EZGO: Troubleshooting an Alltrax NCX300DCS: Electric …Re: Troubleshooting an Alltrax NCX300DCS. Check the voltage of the pack and each battery. Ideally 12 hours after a charge, but a bad battery should show up regardless. Each battery should be within .1 volts of the others. Just 'cause they're new, doesn't mean they're good.Alltrax speed controller disappointment. Just got CC IQ decided to upgrade. Upgrades include plum quick bandit. Lift kit. 23 inch tires. Alltrax 500 amp. Kart was going 25 mph with new PQ motor & stock controler on speed 4 setting. Kart is now going 20 with new Alltrax contoler. Has a little more torque off line but the power falls off and it ...Posts: 5. Re: Curtis 1268 - HPD Fault. 2009 Excel you may have a TPS converted to MCOR, there are some resistors inside the converter harness box. The resistors have been reported to fail. Measure the resistance between the mcor wires from the controller 16 pin plug to the MCOR 3 pin plug. You should have about 453 ohms.Group 2: 2-Green + Red alarm code is a condition that may inhibit or cause the controller to stop, but is not a hard fault, rather a condition that requires attention. Group 3: 3-Green + Red alarm code is an uncalibrated throttle, clear the throttle calibration and try again. The program may also have a fault or loaded or updated incorrectly.Product Description. Alltrax SR-48600 Motor Controller. - Fan, Fuse & Mounting Hardware Included. - For Series and Permanent Magnet Motors. Features. Color coded terminals. 12-48 Volts. 600 Amps Peak. 690 (Peak Amp Mode)Controllers. DO NOT Use with Alltrax Controller Heavy Duty — Maximum performance, high speed, maximum torque, pulling loads, hilly terrain or Hunting Buggies. Performance 200 AMP (600amp Inrush) Use with 300 and 400 AMP Controllers Heavy Duty 200 AMP (800A surge) Use with 300 to 500 AMP Controllers Heavy Duty 400 AMP (1000A surge) Use with ...Pre-charge failure on an XCT is sort of a code red since it uses no pre-charge resistor and the pre-charge is internal. Take 2 aspirin & call Alltrax in the morning 541-476-3565EZGO 36 volt TXT PDS will not move forward or reverse. No clicking in controller. Have replaced curtis controller with AllTrax controller, still no movement. Replaced the key switch, forward / reverse … read moreThe throttle code blinks on controller power up and alarm codes blink when the alarm happens. All alarms are self clearing so when the alarm event is over, the controller resumes normal operation, except for the Short Circuit alarm that needs a power off cycle to clear the alarm. throttle codes: 1 Green LED Flash = 0-5k throttleI have a 2017 EZGO TXT 48v cart that was lifted and modified by a company called Trail Hog. I was told the Curtis SepEx Model 1268 Motor Controller was bad so I purchased a new one along with a new solenoid. The new controller and solenoid was installed and it ran good for about a day.Yesterday, I installed a new Alltrax SPM 48500 controller, heavy duty solenoid, heavy duty f/r switch, D&D 170-010-0002 speed and torque motor, and heavy duty cables. I powered the cart up after installing everything and the cart didn't move an inch. I looked at the controller and noticed the Led indicator light was blinking 2 green lights ...Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected]D&D Alltrax Golf Cart Motor Controller Beep Light Flash Codes For Series. Bruno 8 years ago 0 3 mins. Having troubles with your golf cart that uses a D&D Alltrax …To fix the LED light blinking 7 times-. Firstly, check the voltage between Control B+ and B-. If the voltage on the battery is +/-5V higher than the pack voltage, check the wires connected to the solenoid. In care any of the wires connecting to the solenoid are damaged or broken, replace or fix the wires accordingly.Flash Code on Outdoor Board: 3 for 38TDB, YDB 598B, 698B models and 53 for 24ANA, 25HNA 187A, 180A, 286A, 288A. Fault description: Outside Temp Sensor issue. Potential cause and action: Ohm out sensor and check wiring. May also indicate lost communication with the outdoor unit. Flash Code on Outdoor Board: 4 for 38TDB, YDB 598B, 698B …Hardware: Use a STRAIGHT-THROUGH DB-9 pin / RS-232 serial interface cable to connect the controller to the PC. Alternatively use the preferred DB-9 pin RS-232 serial port to USB adapter. The DCX controller must be powered before the ControllerPRO program will have any effect. Before programming the DCX, READ THE SAFETY NOTES BELOW.. (both red and green lights on) anyway - what model Alltrax control Plug in controller to computer. 2. Turn key switch to ON posi Safety Notes. Alltrax recommends that all motor controller applications must have a fuse in the battery circuit. Failure to utilize a fuse will result in injury, property damage, and void all warranties. Approved fuses manufactured by Bussman or Littelfuse: Controllers rated at 400 amps (or less) use ANN250 Fuse.Alltrax Inc 1111 Cheney Creek Rd Grants Pass, Or, 97527 Direct: 541-476-3565 Fax: 541-476-3566 Alltrax Bluetooth® Modules for XCT Motor Controllers and XCT / BMS Lithium Systems File: DOC113-0018-H_BLUETOOTH-Operators Manual.pdf, Released Rev H, EC-072519 ALLTRAX PN: BLUETOOTH-MODULE (As released FCC Part 15B Test completed 10/21/2019) Programming the Controller. 28. Blink Codes. 29. Warran 4. Contact Alltrax for Troubleshooting. Personal Experience: Faced with a non-responsive controller, reaching out to Alltrax's customer service proved invaluable. Steps: Gather Information: Note down your controller's model, serial number, and a brief description of the issue.Okay so I was able to find out that I may have a programming issue! So after connecting to a laptop I found that when they programmed it they set the controller as if it was apparently going to be hooked to 48v because the under voltage was set too high for a 36v cart. LED Blink Codes: When I power up my Alltrax cont...

Continue Reading